Datasheet

2012-2013 Microchip Technology Inc. DS30009312B-page 441
PIC24FJ128GC010 FAMILY
TABLE 37-27: RESET AND BROWN-OUT RESET REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.0V to 3.6V (unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
Param
No.
Symbol Characteristic Min Typ Max Units Conditions
SY10 T
MCL MCLR Pulse Width (Low) 2 s
SY12 TPOR Power-on Reset Delay 2 s
SY13 T
IOZ I/O High-Impedance from
MCLR
Low or Watchdog
Timer Reset
Lesser of:
(3 T
CY + 2)
or 700
—(3T
CY + 2) s
SY25 TBOR Brown-out Reset Pulse
Width
1—sVDD VBOR
SY45 TRST Internal State Reset Time 50 s
SY70 T
DSWU Deep Sleep Wake-up
Time
200 sVCAP fully discharged
before wake-up
SY71 T
PM Program Memory
Wake-up Time
—20s Sleep wake-up with
PMSLP = 0
—1s Sleep wake-up with
PMSLP = 1
SY72 T
LVR Low-Voltage Regulator
Wake-up Time
—90s Sleep wake-up with
PMSLP = 0
—70s Sleep wake-up with
PMSLP = 1