4.3 SERIAL/I
2
C COMMUNICATIONS DO NOT WORK
If the PICDEM Lab II serial interface is not recognized by the ASYNC terminal
program:
- Verify that the serial driver for the MCP2221 is correctly loaded.
- Verify the USB interface cable is firmly seated in the PICDEM Lab II board.
- Verify the USB interface cable is firmly seated in the USB port of the
computer.
- Verify the USB port used is working.
- Verify that power and GND are connected to pins 2 and 3 of J4 and that
voltage is present at the connector.
If the problem persists, contact Microchip’s help line for further assistance.
If the PICDEM Lab II serial interface is not recognized by the I
2
C/SMBus terminal
program:
- Verify that the I
2
C/SMBus terminal program is correctly loaded.
- Verify the USB interface cable is firmly seated in the PICDEM Lab II board.
- Verify the USB interface cable is firmly seated in the USB port of the
computer.
- Verify the USB port used is working.
- Verify that power and GND are connected to pins 2 and 3 of J4 and that
voltage is present at the connector.
- Verify pull-up resistors are present on the SDA and SCL (pins 4 and 5) lines of J4.
If the problem persists, contact Microchip’s help line for further assistance.