Datasheet
2012-2013 Microchip Technology Inc. Advance Information DS40001667C-page 25
MGC3130
FIGURE 6-1: GESTURE PORT MAPPING
The Colibri Suite can generate up to eight event
outputs which can be mapped to any EIO (1, 2, 3, 6 or
7). It is also possible to map more than one event
output by one EIO.
EventOutput1..8
To EIOs
Gesture Selection
[0:2]
Electrode Selection
[0:2]
Gesture
Wake-up after Approach Detection
Action Selection
[0:2]
EventInput
Selection [0:1]
Sensor Touch
Flick West -> East
Flick East -> West
Flick North -> South
Flick South -> North
Circle ClockWise
Circle Counter-ClockWise
Permanent high
Permanent low
Sensor Touch
Selection [0:1]
Touch
Tap
Double Tap
Colibri Suite Events
MGC3130 Pins Events mapping
High active
Low active
Toggle
Pulse (5ms)
EIO1,2,3,6,7
EventOutput 1
EventOutput 8
...