Datasheet

2012-2013 Microchip Technology Inc. Advance Information DS40001667C-page 19
MGC3130
FIGURE 4-7: CURRENT CONSUMPTION FOR VARYING TIME INTERVALS BETWEEN
APPROACH SCANS AND CALIBRATION SCANS
FIGURE 4-8: CURRENT CONSUMPTION FOR A FIXED TIME INTERVAL BETWEEN
APPROACH SCANS OF 20 ms
0,11
0,77
0,57
1,21
0,20
0,86
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
0 50 100 150 200
Current Consumption [mA]
Time Interval between Approach Scans[ms]
no Calibration Scan
Calibration Scan every 2s
Calibration Scan every 10s
1,21
1,07
0,99
0,95
0,92
0,90
0,88
0,87
0,86
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
024681012
Current Consumption (mA)
Time interval between Calibration Scans (s)