FIGURE 5-3: TIMING SEQUENCE OF RX INDICATION AFTER POWER-ON STATE
FIGURE 5-4: TIMING SEQUENCE OF POWER-OFF STATE
Note 1: EEPROM clock = 100 kHz.
2: For a byte write: 0.01 ms x 32 clock x 2 = 640 μs.
3: It is recommended to have ramp-down time more than 640 μs during the power-off sequence to
ensure safe operation of the device.