32.2.4 Wake-up time from sleep modes
Table 32-34. Device wake-up time from sleep modes with various system clock sources.
Note: 1. The wake-up time is the time from the wake-up request is given until the peripheral clock is available on pin, see Figure 32-9. All peripherals and modules start
execution from the first clock cycle, expect the CPU that is halted for four clock cycles before program execution starts.
Figure 32-9. Wake-up time definition.
Symbol Parameter Condition Min. Typ.
(1)
Max. Units
t
wakeup
Wake-up time from idle,
standby, and extended standby
mode
External 2MHz clock 2.0
µs
32.768kHz internal oscillator 120
2MHz internal oscillator 2.0
32MHz internal oscillator 0.2
Wake-up time from power-save
and power-down mode
External 2MHz clock 5.0
32.768kHz internal oscillator 320
2MHz internal oscillator 9.0
32MHz internal oscillator 5.0
Wakeup request
Clock output
Wakeup time