Datasheet

84
XMEGA D4 [DATASHEET]
8135P–AVR–01/2014
32.2.3 Current consumption
Table 32-32. Current consumption for Active mode and sleep modes.
Notes: 1. All Power Reduction Registers set.
2. Maximum limits are based on characterization, and not tested in production.
Symbol Parameter Condition Min. Typ. Max. Units
I
CC
Active power
consumption
(1)
32kHz, Ext. Clk
V
CC
= 1.8V 40
µA
V
CC
= 3.0V 80
1MHz, Ext. Clk
V
CC
= 1.8V 200
V
CC
= 3.0V 410
2MHz, Ext. Clk
V
CC
= 1.8V 350 600
V
CC
= 3.0V
0.75 1.4
mA
32MHz, Ext. Clk 7.5 12
Idle power
consumption
(1)
32kHz, Ext. Clk
V
CC
= 1.8V 2.0
µA
V
CC
= 3.0V 2.8
1MHz, Ext. Clk
V
CC
= 1.8V 42
V
CC
= 3.0V 85
2MHz, Ext. Clk
V
CC
= 1.8V 85 225
V
CC
= 3.0V
170 350
32MHz, Ext. Clk 2.7 5.5 mA
Power-down power
consumption
T=25°C
V
CC
= 3.0V
0.1 1.0
µA
T=85°C 2.0 4.5
WDT and sampled BOD enabled,
T=25°C
V
CC
= 3.0V
1.4 3.0
WDT and sampled BOD enabled,
T = 85°C
3.0 6.0
Power-save power
consumption
(2)
RTC from ULP clock, WDT and
sampled BOD enabled, T = 25°C
V
CC
= 1.8V 1.5
V
CC
= 3.0V 1.5
RTC from 1.024kHz low power
32.768kHz TOSC, T = 25°C
V
CC
= 1.8V 0.6 2.0
V
CC
= 3.0V 0.7 2.0
RTC from low power 32.768kHz
TOSC, T = 25°C
V
CC
= 1.8V 0.8 3.0
V
CC
= 3.0V 1.0 3.0
Reset power consumption
Current through RESET pin
substracted
V
CC
= 3.0V 300