8135P–AVR–01/2014
Some timer/counters have extensions to enable more specialized waveform and frequency generation. The advanced
waveform extension (AWeX) is intended for motor control and other power control applications. It enables low- and high-
side output with dead-time insertion, as well as fault protection for disabling and shutting down external drivers. It can
also generate a synchronized bit pattern across the port pins.
The advanced waveform extension can be enabled to provide extra and more advanced features for the Timer/Counter.
This are only available for Timer/Counter 0. See “AWeX – Advanced Waveform Extension” on page 35 for more details.
The high-resolution (hi-res) extension can be used to increase the waveform output resolution by four or eight times by
using an internal clock source running up to four times faster than the peripheral clock. See “Hi-Res – High Resolution
Extension” on page 36 for more details.
Figure 15-1. Overview of a Timer/Counter and closely related peripherals.
PORTC has one Timer/Counter 0 and one Timer/Counter1. PORTD and PORTE each has one Timer/Conter0. Notation
of these are TCC0 (Time/Counter C0), TCC1, TCD0 and TCE0, respectively.
AWeX
Compare/Capture Channel D
Compare/Capture Channel C
Compare/Capture Channel B
Compare/Capture Channel A
Waveform
Generation
Buffer
Comparator
Hi-Res
Fault
Protection
Capture
Control
Base Counter
Counter
Control Logic
Timer Period
Prescaler
Dead-Time
Insertion
Pattern
Generation
clk
PER4
PORT
Event
System
clk
PER
Timer/Counter