8135P–AVR–01/2014
Table 32-90. Current consumption for modules and peripherals.
Note: 1. All parameters measured as the difference in current consumption between module enabled and disabled. All data at V
CC
= 3.0V, Clk
SYS
= 1MHz external clock
without prescaling, T = 25°C unless other conditions are given.
Symbol Parameter Condition
(1)
Min. Typ. Max. Units
I
CC
ULP oscillator 1.0
µA
32.768kHz int. oscillator 27
2MHz int. oscillator
85
DFLL enabled with 32.768kHz int. osc. as reference 115
32MHz int. oscillator
270
DFLL enabled with 32.768kHz int. osc. as reference 460
PLL
20x multiplication factor,
32MHz int. osc. DIV4 as reference
220
Watchdog Timer 1.0
BOD
Continuous mode 138
Sampled mode, includes ULP oscillator 1.2
Internal 1.0V reference 100
Temperature sensor 95
ADC
150ksps
V
REF
= Ext ref
3.0
mA
CURRLIMIT = LOW 2.6
CURRLIMIT = MEDIUM 2.1
CURRLIMIT = HIGH 1.6
AC High Speed Mode 330
µATimer/Counter 16
USART Rx and Tx enabled, 9600 BAUD 2.5
Flash memory and EEPROM programming 4 8 mA