Datasheet

286
XMEGA B [DATASHEET]
8291B–AVR–01/2013
For reception, a fixed programmable minimum high-level pulse width for the pulse to be decoded as a logical 0 is used.
Shorter pulses will then be discarded, and the bit will be decoded to logical 1 as if no pulse was received.
The module can only be used in combination with one USART at a time. Thus, IRCOM mode must not be set for more
than one USART at a time. This must be ensured in the user software.
22.2.1 Event System Filtering
The event system can be used as the receiver input. This enables IRCOM or USART input from I/O pins or sources other
than the corresponding RX pin. If event system input is enabled, input from the USART's RX pin is automatically
disabled. The event system has a digital input filter (DIF) on the event channels that can be used for filtering. Refer to
“Event System” on page 65” for details on using the event system.