Datasheet
XMEGA A4U [DATASHEET]
Atmel-8387G-AVR-ATxmega16A4U-34A4U-64A4U-128A4U-Datasheet_03/2014
332
3. AWeX fault protection restore is not done correct in Pattern Generation Mode
When a fault is detected the OUTOVEN register is cleared, and when fault condition is cleared, OUTOVEN
is restored according to the corresponding enabled DTI channels. For Common Waveform Channel Mode
(CWCM), this has no effect as the OUTOVEN is correct after restoring from fault. For Pattern Generation
Mode (PGM), OUTOVEN should instead have been restored according to the DTLSBUF register.
Problem fix/Workaround
For CWCM no workaround is required.
For PGM in latched mode, disable the DTI channels before returning from the fault condition. Then, set cor-
rect OUTOVEN value and enable the DTI channels, before the direction (DIR) register is written to enable
the correct outputs again.
38.3.3 Rev. A - B
Not sampled.