Datasheet
86
XMEGA C4 [DATASHEET]
8493G–AVR–01/2014
Table 33-34. Current consumption for modules and peripherals.
Note: 1. All parameters measured as the difference in current consumption between module enabled and disabled. All data at V
CC
= 3.0V, Clk
SYS
= 1MHz external clock
without prescaling, T = 25°C unless other conditions are given.
Symbol Parameter Condition
(1)
Min. Typ. Max. Units
I
CC
ULP oscillator 0.8
µA
32.768kHz int. oscillator 29
2MHz int. oscillator
85
DFLL enabled with 32.768kHz int. osc. as reference 115
32MHz int. oscillator
245
DFLL enabled with 32.768kHz int. osc. as reference 410
PLL
20x multiplication factor,
32MHz int. osc. DIV4 as reference
290
Watchdog timer 1.0
BOD
Continuous mode 138
Sampled mode, includes ULP oscillator 1.2
Internal 1.0V reference 175
Temperature sensor 170
ADC
16ksps
V
REF
= Ext ref
1.2
mA
CURRLIMIT = LOW 1.0
CURRLIMIT = MEDIUM 0.9
CURRLIMIT = HIGH 0.8
75ksps
V
REF
= Ext ref
CURRLIMIT = LOW 1.7
300ksps
V
REF
= Ext ref
3.1
USART Rx and Tx enabled, 9600 BAUD 11 µA
Flash memory and EEPROM programming 4 mA