Datasheet

97
8116J–AVR–06/2013
XMEGA A3B
Not recommended for new designs -
Use ATxmega256A3BU
Problem fix/Workaround
None.
7. Configuration of PGM and CWCM not as described in XMEGA A Manual
Enabling Common Waveform Channel Mode will enable Pattern generation mode (PGM),
but not Common Waveform Channel Mode.
Enabling Pattern Generation Mode (PGM) and not Common Waveform Channel Mode
(CWCM) will enable both Pattern Generation Mode and Common Waveform Channel Mode.
Problem fix/Workaround
8. PWM is not restarted properly after a fault in cycle-by-cycle mode
When the AWeX fault restore mode is set to cycle-by-cycle, the waveform output will not
return to normal operation at first update after fault condition is no longer present.
Problem fix/Workaround
Do a write to any AWeX I/O register to re-enable the output.
9. BOD will be enabled after any reset
If any reset source goes active, the BOD will be enabled and keep the device in reset if the
VCC voltage is below the programmed BOD level. During Power-On Reset, reset will not be
released until VCC is above the programmed BOD level even if the BOD is disabled.
Problem fix/Workaround
Do not set the BOD level higher than VCC even if the BOD is not used.
10. DAC is nonlinear and inaccurate when reference is above 2.4V or VCC - 0.6V
Using the DAC with a reference voltage above 2.4V or VCC - 0.6V will give inaccurate out-
put when converting codes that give below 0.75V output:
±10 LSB for continuous mode
±200 LSB for Sample and Hold mode
Problem fix/Workaround
None.
11. DAC has increased INL or noise for some operating conditions
Some DAC configurations or operating condition will result in increased output error.
Continous mode: ±5 LSB
Sample and hold mode: ±15 LSB
Sample and hold mode for reference above 2.0v: up to ±100 LSB
Problem fix/Workaround
None.
Table 36-1. Configure PWM and CWCM according to this table:
PGM CWCM Description
0 0 PGM and CWCM disabled
0 1 PGM enabled
1 0 PGM and CWCM enabled
1 1 PGM enabled