Datasheet

40
8116J–AVR–06/2013
XMEGA A3B
Not recommended for new designs -
Use ATxmega256A3BU
23. IRCOM - IR Communication Module
23.1 Features
Pulse modulation/demodulation for infrared communication
Compatible to IrDA 1.4 physical for baud rates up to 115.2 kbps
Selectable pulse modulation scheme
3/16 of baud rate period
Fixed pulse period, 8-bit programmable
Pulse modulation disabled
Built in filtering
Can be connected to and used by one USART at a time
23.2 Overview
XMEGA A3B contains an Infrared Communication Module (IRCOM) for IrDA communication
with baud rates up to 115.2 kbps. This supports three modulation schemes: 3/16 of baud rate
period, fixed programmable pulse time based on the Peripheral Clock speed, or pulse modula-
tion disabled. There is one IRCOM available which can be connected to any USART to enable
infrared pulse coding/decoding for that USART.