Datasheet

348
XMEGA B [DATASHEET]
8291B–AVR–01/2013
26.16.7 SCAN – Input Channel Scan register
Scan is enabled when COUNT is set differently than 0.
Bit 7:4 – OFFSET[3:0]: Positive MUX Setting Offset
The channel scan is enabled when COUNT != 0 and this register contains the offset for the next input source to be
converted on ADC channel. The actual MUX setting for positive input equals MUXPOS + OFFSET. The value is
incremented after each conversion until it reaches the maximum value given by COUNT. When OFFSET is equal to
COUNT, OFFSET will be cleared on the next conversion.
Bit 3:0 – COUNT[3:0]: Number of Input Channels Included in Scan
This register gives the number of input sources included in the channel scan. The number of input sources included is
COUNT + 1. The input channels included are the range from MUXPOS to MUXPOS + COUNT.
Bit 76543210
+0x06 OFFSET[3:0] COUNT[3:0]
Read/Write R/W R/W R/W R/W R/W R/W R/W R/W
Initial Value 0 0 0 0 0 0 0 0