Datasheet

202
XMEGA B [DATASHEET]
8291B–AVR–01/2013
17.2.1 Clock Domains
The RTC is asynchronous, operating from a different clock source independently of the main system clock and its
derivative clocks, such as the peripheral clock. For control and count register updates, it will take a number of RTC clock
and/or peripheral clock cycles before an updated register value is available in a register or until a configuration change
has effect on the RTC. This synchronization time is described for each register. Refer to “RTCCTRL – RTC Control
register” on page 84 for selecting the asynchronous clock source for the RTC.
17.2.2 Interrupts and Events
The RTC can generate both interrupts and events. The RTC will give a compare interrupt and/or event at the first count
after the counter value equals the Compare register value. The RTC will give an overflow interrupt request and/or event
at the first count after the counter value equals the Period register value. The overflow will also reset the counter value to
zero.
Due to the asynchronous clock domain, events will be generated only for every third overflow or compare match if the
period register is zero. If the period register is one, events will be generated only for every second overflow or compare
match. When the period register is equal to or above two, events will trigger at every overflow or compare match, just as
the interrupt request.