15.4 Dead-time Insertion
The dead-time insertion (DTI) unit generates OFF time where the non-inverted low side (LS) and inverted high side (HS)
of the WG output are both low. This OFF time is called dead time, and dead-time insertion ensures that the LS and HS
never switch simultaneously.
The DTI unit consists of four equal dead-time generators, one for each compare channel in timer/counter 0. Figure 15-3
on page 191 shows the block diagram of one DTI generator. The four channels have a common register that controls the