ATUC64/128/256L3/4U
Figure 30-3. The Filtering Algorithm
30.7 Peripheral Event Triggers
Peripheral events from other modules can trigger comparisons in the ACIFB. All channels that
are set up in Event Triggered Single Measurement Mode will be started simultaneously when a
peripheral event is received. Channels that are operating in Continuous Measurement Mode or
User Triggered Single Measurement Mode will be unaffected by the received event. The soft-
ware can still operate these channels independently of channels in Event Triggered Single
Measurement Mode.
A peripheral event will trigger one or more comparisons, in normal or window mode.
30.8 AC Test mode
By writing the Analog Comparator Test Mode (CR.ACTEST) bit to one, the outputs from the ACs
are overridden by the value in the Test Register (TR), see Figure 30-1. This is useful for software
development.
2
FLEN
2
FLEN
2
HYS HYS
”Result=0" ”Result=1"
Result =
UNCHANGED
0