ATUC64/128/256L3/4U
This bit is set when pen contact is detected and pen detect is enabled.
OVRE: Overrun Error Status
This bit is cleared when no Overrun Error has occurred since the start of a conversion sequence.
This bit is set when one or more Overrun Error has occurred since the start of a conversion sequence.
DRDY: Data Ready Status
0: No data has been converted since the last reset.
1: One or more conversions have completed since the last reset and data is available in LCDR.
This bit is cleared when CR.SWRST is written to one.
This bit is set when one or more conversions have completed and data is available in LCDR.