The RA Loading Selection field in CMRn (CMRn.LDRA) defines the TIOA edge for the loading of
the RA register, and the RB Loading Selection field in CMRn (CMRn.LDRB) defines the TIOA
edge for the loading of the RB register.
RA is loaded only if it has not been loaded since the last trigger or if RB has been loaded since
the last loading of RA.
RB is loaded only if RA has been loaded since the last trigger or the last loading of RB.
Loading RA or RB before the read of the last value loaded sets the Load Overrun Status bit in
SRn (SRn.LOVRS). In this case, the old value is overwritten.
26.6.2.2 Trigger conditions
In addition to the SYNC signal, the software trigger and the RC compare trigger, an external trig-
ger can be defined.
The TIOA or TIOB External Trigger Selection bit in CMRn (CMRn.ABETRG) selects TIOA or
TIOB input signal as an external trigger. The External Trigger Edge Selection bit in CMRn
(CMRn.ETREDG) defines the edge (rising, falling or both) detected to generate an external trig-
ger. If CMRn.ETRGEDG is zero (none), the external trigger is disabled.