Datasheet

393
32142D–06/2013
ATUC64/128/256L3/4U
18.6.3 Status Register
Name:
STATUS
Access Type: Read-only
Offset: 0x008
Reset Value: 0x00000000
RCLKBUSY: FREQM Reference Clock Status
0: The FREQM ref clk is ready, so a measurement can start.
1: The FREQM ref clk is not ready, so a measurement should not be started.
BUSY: FREQM Status
0: The Frequency Meter is idle.
1: Frequency measurement is on-going.
31 30 29 28 27 26 25 24
--------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
--------
76543210
------RCLKBUSYBUSY