Datasheet
298
32142D–06/2013
ATUC64/128/256L3/4U
14.6.26 High Resolution Prescaler Control Register
Name:
HRPCR
Access Type: Read/Write
Reset Value: 0x00000000
• HRCOUNT: High Resolution Counter
Specify the input clock period to count to generate the output clock edge.
HRCOUNT can be written to dynamically in order to tune the HRPCLK frequency on-the-go.
• CKSEL: Clock input selection
This field selects the Clock input for the prescaler. See the “HRP clock sources” table in the SCIF Module Configuration section
for details. It must not be changed if the HRPEN is one.
• HRPEN: High Resolution Prescaler Enable
0: The High Resolution Prescaler is disabled.
1: The High Resolution Prescaler is enabled.
31 30 29 28 27 26 25 24
HRCOUNT[23:16]
23 22 21 20 19 18 17 16
HRCOUNT[15:8]
15 14 13 12 11 10 9 8
HRCOUNT[7:0]
76543210
- - - - CKSEL HRPEN