Datasheet

619
32133D–11/2011
UC3D
This bit is cleared when the corresponding bit in SCR is written to one
LOVR:Sequencer last converted value overrun
This bit is set when an overrun error occurs on the LCV register
This bit is cleared when the corresponding bit in SCR is written to one
SEOC:Sequencer end of conversion
This bit is set when an end of conversion occurs
This bit is cleared when the corresponding bit in SCR is written to one
SEOS:Sequencer end of sequence
This bit is set when an end of sequence occurs
This bit is cleared when the corresponding bit in SCR is written to one
SSOS:Sequencer start of sequence
This bit is set when a start of sequence occurs
This bit is cleared when the corresponding bit in SCR is written to one