Datasheet
619
32133D–11/2011
UC3D
This bit is cleared when the corresponding bit in SCR is written to one
• LOVR:Sequencer last converted value overrun
This bit is set when an overrun error occurs on the LCV register
This bit is cleared when the corresponding bit in SCR is written to one
• SEOC:Sequencer end of conversion
This bit is set when an end of conversion occurs
This bit is cleared when the corresponding bit in SCR is written to one
• SEOS:Sequencer end of sequence
This bit is set when an end of sequence occurs
This bit is cleared when the corresponding bit in SCR is written to one
• SSOS:Sequencer start of sequence
This bit is set when a start of sequence occurs
This bit is cleared when the corresponding bit in SCR is written to one