559
32133D–11/2011
UC3D
• CPBS: RB Compare Status
1: This bit is set when an RB Compare has occurred and CMRn.WAVE is one.
0: This bit is cleared when the SR register is read.
• CPAS: RA Compare Status
1: This bit is set when an RA Compare has occurred and CMRn.WAVE is one.
0: This bit is cleared when the SR register is read.
• LOVRS: Load Overrun Status
1: This bit is set when RA or RB have been loaded at least twice without any read of the corresponding register and
CMRn.WAVE is zero.
0: This bit is cleared when the SR register is read.
• COVFS: Counter Overflow Status
1: This bit is set when a counter overflow has occurred.
0: This bit is cleared when the SR register is read.