Datasheet

158
32133D–11/2011
UC3D
13.6.11 Bandgap Calibration Register
Name: BGCR
Access Type: Read/Write
Offset: 0x002C
Reset Value: 0x00000000
SFV: Store Final Value
0: The register is read/write
1: The register is read-only, to protect against further accidental writes.
FCD: Flash Calibration Done
Set to 1 when the CALIB field has been updated by the Flash fuses after power-on reset or when the Flash fuses are
reprogrammed. The CALIB field will not be updated again by the Flash fuses until a new power-on reset or the FCD field is
written to zero.
CALIB: Calibration value
Calibration value for Bandgap. See Electrical Characteristics for voltage values.
Note that this register is protected by a lock. To write to this register the UNLOCK register has to be written first. Please
refer to the UNLOCK register description for details.
31 30 29 28 27 26 25 24
SFV-------
23 22 21 20 19 18 17 16
-------FCD
15 14 13 12 11 10 9 8
--------
7654321
0
----- CALIB