Datasheet

194
7701F–AVR–10/12
Atmel ATtiny24/44/84 [Preliminary]
23.3 Supply Current of IO modules
The tables and formulas below can be used to calculate the additional current consumption for
the different I/O modules in Active and Idle mode. The enabling or disabling of the I/O modules
are controlled by the Power Reduction Register. See “Power Reduction Register” on page 36
for details.
23.4 Power-down Supply Current
Figure 23-13. Power-down Supply Current vs. V
CC
(Watchdog Timer Disabled)
Table 23-1. Additional Current Consumption for the different I/O modules (absolute values)
PRR bit Typical numbers
V
CC
= 2V, F = 1MHz V
CC
= 3V, F = 4MHz V
CC
= 5V, F = 8MHz
PRTIM1 6.6µA 26µA 106µA
PRTIM0 8.7µA 35µA 140µA
PRUSI 5.5µA 22µA 87µA
PRADC 22µA 87µA 340µA
POWER-DOWN SUPPLY CURRENT vs. V
CC
WATCHDOG TIMER DIS ABLED
125 ˚C
85 ˚C
25 ˚C
-45 ˚C
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
2.53 3.54 4.555.5
V
CC
(V)
I