Figure 8. Single Cycle ALU Operation
4.7 Reset and Interrupt Handling
The AVR provides several different interrupt sources. These interrupts and the separate Reset Vector each have a
separate Program Vector in the Program memory space. All interrupts are assigned individual enable bits which must be
written logic one together with the Global Interrupt Enable bit in the Status Register in order to enable the interrupt.
Depending on the value of the program counter, interrupts may be automatically disabled when Boot Lock Bits (BLB02 or
BLB12) are programmed. This feature improves software security. See section “Lock Bits” on page 225 for details.
The lowest addresses in the Program memory space are by default defined as the Reset and Interrupt Vectors. The
complete list of vectors is shown in “Interrupts” on page 48. The list also determines the priority levels of the different
interrupts. The lower the address the higher is the priority level. RESET has the highest priority, and next is INT0 – the
External Interrupt Request 0.
The interrupt vector table can be moved to the start of Flash boot section by setting the IVSEL bit. For more information,
see “MCUCR – MCU Control Register” on page 53 and “Interrupts” on page 48. The reset vector can also be moved to
the start of Flash boot section by programming the BOOTRST fuse. See “Entering the Boot Loader Program” on page
216.
When an interrupt occurs, the Global Interrupt Enable I-bit is cleared and all interrupts are disabled. The user software
can write logic one to the I-bit to enable nested interrupts. All enabled interrupts can then interrupt the current interrupt
routine. The I-bit is automatically set when a Return from Interrupt instruction – RETI – is executed.
There are basically two types of interrupts. The first type is triggered by an event that sets the Interrupt Flag. For these
interrupts, the Program Counter is vectored to the actual Interrupt Vector in order to execute the interrupt handling
routine, and hardware clears the corresponding Interrupt Flag. Interrupt Flags can also be cleared by writing a logic one
to the flag bit position(s) to be cleared. If an interrupt condition occurs while the corresponding interrupt enable bit is
cleared, the Interrupt Flag will be set and remembered until the interrupt is enabled, or the flag is cleared by software.
Similarly, if one or more interrupt conditions occur while the Global Interrupt Enable bit is cleared, the corresponding
Interrupt Flag(s) will be set and remembered until the Global Interrupt Enable bit is set, and will then be executed by
order of priority.
The second type of interrupts will trigger as long as the interrupt condition is present. These interrupts do not necessarily
have Interrupt Flags. If the interrupt condition disappears before the interrupt is enabled, the interrupt will not be
triggered.
When the AVR exits from an interrupt, it will always return to the main program and execute one more instruction before
any pending interrupt is served.
Note that the Status Register is not automatically stored when entering an interrupt routine, nor restored when returning
from an interrupt routine. This must be handled by software.
Total Execution Time
Register Operands Fetch
ALU Operation Execute
Result Write Back
T1 T2 T3 T4
clk
CPU