Datasheet
189
8197C–AVR–05/11
ATtiny261A/461A/861A
19.5.1 Enhanced Power-On Reset
Note: 1. Values are guidelines, only.
2. Threshold where device is released from reset when voltage is rising.
3. The Power-on Reset will not work unless the supply voltage has been below V
POA
.
19.5.2 Brown-Out Detection
Note: 1. V
BOT
may be below nominal minimum operating voltage for some devices. For devices where
this is the case, the device is tested down to V
CC
= V
BOT
during the production test. This guar-
antees that a Brown-out Reset will occur before V
CC
drops to a voltage where correct
operation of the microcontroller is no longer guaranteed.
Table 19-5. Characteristics of Enhanced Power-On Reset. T
A
= -40 to +85°C
Symbol Parameter Min
(1)
Typ
(1)
Max
(1)
Units
V
POR
Release threshold of power-on reset
(2)
1.1 1.4 1.6 V
V
POA
Activation threshold of power-on reset
(3)
0.6 1.3 1.6 V
SR
ON
Power-On Slope Rate 0.01 V/ms
Table 19-6. BODLEVEL Fuse Coding
(1)
BODLEVEL[2:0] Fuses Min V
BOT
Typ V
BOT
Max V
BOT
Units
111 BOD Disabled
110 1.7 1.8 2.0
V101 2.5 2.7 2.9
100 4.1 4.3 4.5
0XX Reserved