Datasheet
146
ATtiny2313/V
2543H–AVR–02/05
USI Control Register – USICR
The Control Register includes interrupt enable control, wire mode setting, Clock Select
setting, and clock strobe.
• Bit 7 – USISIE: Start Condition Interrupt Enable
Setting this bit to one enables the Start Condition detector interrupt. If there is a pending
interrupt when the USISIE and the Global Interrupt Enable Flag is set to one, this will
immediately be executed.
• Bit 6 – USIOIE: Counter Overflow Interrupt Enable
Setting this bit to one enables the Counter Overflow interrupt. If there is a pending inter-
rupt when the USIOIE and the Global Interrupt Enable Flag is set to one, this will
immediately be executed.
• Bit 5..4 – USIWM1..0: Wire Mode
These bits set the type of wire mode to be used. Basically only the function of the
outputs are affected by these bits. Data and clock inputs are not affected by the mode
selected and will always have the same function. The counter and Shift Register can
therefore be clocked externally, and data input sampled, even when outputs are
disabled. The relations between USIWM1..0 and the USI operation is summarized in
Table 60 on page 147.
Bit 7 6 5 4 3 2 1 0
USISIE USIOIE USIWM1 USIWM0 USICS1 USICS0 USICLK USITC USICR
Read/Write R/W R/W R/W R/W R/W R/W W W
Initial Value 0 0 0 0 0 0 0 0