Datasheet
84
ATtiny13
2535E–AVR–10/04
Figure 46. ADC Timing Diagram, Free Running Conversion
Table 36. ADC Conversion Time
Condition
Sample & Hold (Cycles
from Start of Conversion)
Conversion Time
(Cycles)
First conversion 13.5 25
Normal conversions 1.5 13
Auto Triggered conversions 2 13.5
11 12 13
Sign and MSB of Result
LSB of Result
ADC Clock
ADSC
ADIF
ADCH
ADCL
Cycle Number
12
One Conversion Next Conversion
34
Conversion
Complete
Sample & Hold
MUX and REFS
Update