Datasheet
AVR079
31
8133A-AVR-04/08
Table 8-10. Answer format.
Field Size Values Description
Answer id 1 byte CMD_JTAG_AVR32 Answer id
status 1 byte
RSP_FAILED
RSP_SCAN_CHAIN_READ
data 4 bytes If RSP_SCAN_CHAIN_READ
8.6 CMD_BLOCK_WRITE_AVR32
This command writes a block of data starting at the specified SAB address. N should
be less than 64 to comply with the maximum data buffer of STK600.
Table 8-11. Command format.
Field Size Values Description
AVR32JTAG id 1 byte CMD_JTAG_AVR32 Command id (0x80)
ICE command 1 byte
CMND_JTAG_ BLOCK_WRITE
(0x2d)
count 1 byte n Number of words < 64
SAB address 8 bytes 0 padded, msb first
data n * 4 bytes
Table 8-12. Answer format.
Field Size Values Description
Answer id 1 byte CMD_JTAG_AVR32 Answer id
Status 1 byte
RSP_OK
RSP_FAILED
RSP_ILLEGAL_VALUE
8.7 CMD_ BLOCK_READ_AVR32
This command reads a block of data starting at the specified SAB address. N should
be less than 64 to comply with the maximum data buffer of STK600
Table 8-13. Command format.
Field Size Values Description
AVR32JTAG id 1 byte CMD_JTAG_AVR32 Command id (0x80)
ICE command 1 byte CMND_JTAG_BLOCK_READ (0x2c)
Count 1 byte n Number of words
SAB address 5 bytes