Datasheet

24
AVR079
8133A-AVR-04/08
6.6 CMD_PROGRAM_EEPROM_HVSP
See the CMD_WRITE_FLASH_HVSP command.
XML path: /AVRPART/ICE_SETTINGS/STK600/HvspProgramEeprom/
6.7 CMD_READ_EEPROM_HVSP
See the CMD_READ_FLASH_HVSP command.
XML path: /AVRPART/ICE_SETTINGS/STK600/HvspReadEeprom/
6.8 CMD_PROGRAM_FUSE_HVSP
This command programs one fuse byte, addressed by the Fuse Address byte.
XML path: /AVRPART/ICE_SETTINGS/STK600/HvspProgramFuse/
Table 6-12. Command format.
Field Size Values Description
Command ID 1 byte CMD_PROGRAM_FUSE_HVSP Command id
Fuse Address 1 byte 0, 1 or 2 Address of byte to write (0=low, 1=high, 2=ext)
Fuse Byte 1 byte
Fuse byte value (low, high or ext) to be
programmed
pollTimeout 1 byte XML: pollTimeout Poll timeout
Table 6-13. Answer format.
Field Size Values Description
Answer ID 1 byte CMD_CHIP_ERASE_HVSP Answer id
Status 1 byte STATUS_CMD_OK or
STATUS_RDY_BSY_TOUT
A Result Value indicating the result of the
operation.
6.9 CMD_READ_FUSE_HVSP
This command programs one fuse byte, addressed by the Fuse Address byte.
XML path: /AVRPART/ICE_SETTINGS/STK600/HvspReadFuse/
Table 6-14. Command format.
Field Size Values Description
Command ID 1 byte CMD_ READ_FUSE_HVSP Command id
Fuse Address 1 byte 0, 1 or 2 Address of byte to read (0=low, 1=high, 2=ext)