Datasheet

12
AVR079
8133A-AVR-04/08
4.6 CMD_PROGRAM_EEPROM_ISP
See the CMD_PROGRAM_FLASH_ISP command.
XML path: /AVRPART/ICE_SETTINGS/STK600/IspProgramEeprom/
4.7 CMD_READ_EEPROM_ISP
See the CMD_READ_FLASH_ISP command.
XML path: /AVRPART/ICE_SETTINGS/STK600/IspReadEeprom/
4.8 CMD_PROGRAM_FUSE_ISP
This command programs the fuses of the target device.
Table 4-13. Command format.
Field Size Values Description
Command ID 1 byte CMD_PROGRAM_FUSE_ISP Command id
cmd1
(1)
1 byte Command Byte #1
cmd2
(1)
1 byte Command Byte #2
cmd3
(1)
1 byte Command Byte #3
cmd4
(1)
1 byte Command Byte #4
Notes: 1. cmd1, cmd2, cmd3 and cmd4 are the instruction bytes found in the SPI Serial Programming Instruction Set found in
the device datasheet.
Table 4-14. Answer format.
Field Size Values Description
Answer ID 1 byte CMD_PROGRAM_FUSE_ISP Answer id
Status1 1 byte STATUS_CMD_OK Will always read OK
Status2 1 byte STATUS_CMD_OK Will always read OK
4.9 CMD_READ_FUSE_ISP
This command reads the fuses of the target device.
XML path: /AVRPART/ICE_SETTINGS/STK600/IspReadFuse/
Table 4-15. Command format.
Field Size Values Description
Command ID 1 byte CMD_READ_FUSE_ISP Command id
RetAddr
(1)
1 byte XML: pollIndex Return address
cmd1
(2)
1 byte Command Byte #1
cmd2
(2)
1 byte Command Byte #2
cmd3
(2)
1 byte Command Byte #3
cmd4
(2)
1 byte Command Byte #4