Datasheet

Table Of Contents
574
Atmel | SMART SAM D20 [DATASHEET]
Atmel-42129K–SAM-D20_datasheet–06/2014
32.8.3 Brown-Out Detectors Characteristics
32.8.3.1 BOD33
Table 32-15. BOD33 LEVEL Value
Note: See chapter Memories table “NVM User Row Mapping” for the BOD33 default value settings.
Table 32-16. BOD33 Characteristics
Note: 1. These values are based on simulation. These values are not covered by test limits in production or characterization.
32.8.4 Analog-to-Digital (ADC) characteristics
BOD33.LEVEL Conditions Min. Typ. Max. Units
6
Hysteresis on
- 1.715 1.745
V
7 - 1.750 1.779
39 - 2.84 2.92
48 - 3.2 3.3
6
Hysteresis off
1.62 1.64 1.67
7 1.64 1.675 1.71
39 2.72 2.77 2.81
48 3.0 3.07 3.2
Symbol Parameter Conditions Min. Typ. Max. Units
I
Step size, between
adjacent values in
BOD33.LEVEL
I
- 34 - mV
V
HYST
Hysteresis
I
35 - 170 mV
t
DET
Detection time
Time with V
DDANA
< V
TH
necessary to generate a
reset signal
- 0.9
(1)
- µs
I
BOD33
Current
consumption
Continuous mode 2.9 33 52.2
µA
Sampling mode - 23 75.5
t
STARTUP
Startup time
I
- 2.2
(1)
- µs
Table 32-17. Operating Conditions
Symbol Parameter Conditions Min. Typ. Max. Units
RES Resolution
I
8 - 12 bits
f
CLK_ADC
ADC Clock frequency
I
30 - 2100 kHz
Sample rate
(1)
Single shot 5 - 323 ksps
Free running 5 - 350 ksps