10. The update of these registers will occur at the next PWM period of the synchronous channels when the Update
Period is elapsed. Go to Step 8. for new values.
Figure 39-11. Method 2 (UPDM=1)
Method 3: Automatic write of duty-cycle values and automatic trigger of the update
In this mode, the update of the duty cycle values is made automatically by the Peripheral DMA Controller (PDC). The
update of the period value, the dead-time values and the update period value must be done by writing in their respective
update registers with the CPU (respectively PWM_CPRDUPDx, PWM_DTUPDx and PWM_SCUPUPD).
To trigger the update of the period value and the dead-time values, the user must use the bit UPDULOCK which allows to
update synchronously (at the same PWM period) the synchronous channels:
If the bit UPDULOCK is set to ‘1’, the update is done at the next PWM period of the synchronous channels.
If the UPDULOCK bit is not set to ‘1’, the update is locked and cannot be performed.
After writing the UPDULOCK bit to ‘1’, it is held at this value until the update occurs, then it is read 0.
The update of the duty-cycle values and the update period value is triggered automatically after an update period.
To configure the automatic update, the user must define a value for the Update Period by the field UPR in the
PWM_SCUP register. The PWM controller waits UPR+1 periods of synchronous channels before updating automatically
the duty values and the update period value.
Using the PDC removes processor overhead by reducing its intervention during the transfer. This significantly reduces
the number of clock cycles required for a data transfer, which improves microcontroller performance.
The PDC must write the duty-cycle values in the synchronous channels index order. For example if the channels 0, 1 and
3 are synchronous channels, the PDC must write the duty-cycle of the channel 0 first, then the duty-cycle of the channel
1, and finally the duty-cycle of the channel 3.
The status of the PDC transfer is reported in the PWM_ISR2 by the following flags:
WRDY: this flag is set to ‘1’ when the PWM Controller is ready to receive new duty-cycle values and a new update
period value. It is reset to ‘0’ when the PWM_ISR2 is read. The user can choose to synchronize the WRDY flag
and the PDC transfer request with a comparison match (see Section 39.6.3 “PWM Comparison Units”), by the
fields PTRM and PTRCS in the PWM_SCM register.
ENDTX : this flag is set to ‘1’ when a PDC transfer is completed
TXBUFE : this flag is set to ‘1’ when the PDC buffer is empty (no pending PDC transfers)
UNRE: this flag is set to ‘1’ when the update period defined by the UPR field has elapsed while the whole data has
not been written by the PDC. It is reset to ‘0’ when the PWM_ISR2 is read.