Datasheet
805
SAM4S Series [DATASHEET]
11100F–ATARM–29-Jan-14
• RI: Image of RI Input
0: RI is set to 0.
1: RI is set to 1.
• DSR: Image of DSR Input
0: DSR is set to 0
1: DSR is set to 1.
• DCD: Image of DCD Input
0: DCD is set to 0.
1: DCD is set to 1.
• CTS: Image of CTS Input
0: CTS is set to 0.
1: CTS is set to 1.
• MANERR: Manchester Error
0: No Manchester error has been detected since the last RSTSTA.
1: At least one Manchester error has been detected since the last RSTSTA.