Datasheet

60
SAM4S Series [DATASHEET]
11100F–ATARM–29-Jan-14
12.4.1.13 Priority Mask Register
Name: PRIMASK
Access: Read/Write
Reset: 0x000000000
The PRIMASK register prevents the activation of all exceptions with a configurable priority.
•PRIMASK
0: No effect
1: Prevents the activation of all exceptions with a configurable priority.
31 30 29 28 27 26 25 24
23 22 21 20 19 18 17 16
15 14 13 12 11 10 9 8
76543210
PRIMASK