Datasheet

296
SAM4S Series [DATASHEET]
11100F–ATARM–29-Jan-14
The value obtained must be rounded to the nearest integer prior to being programmed into CORRECTION field.
If HIGHPPM = 1, then the clock frequency correction range is from 30.5 ppm up to 1950 ppm. The RTC accuracy is
less than 1 ppm for a range correction from 30.5 ppm up to 90 ppm.
The correction field must be programmed according to the required correction in ppm; the formula is as follows:
The value obtained must be rounded to the nearest integer prior to be programmed into CORRECTION field.
If NEGPPM is set to 1, the ppm correction is negative.
OUT0: RTCOUT0 OutputSource Selection
OUT1: RTCOUT1 Output Source Selection
Value Name Description
0 NO_WAVE no waveform, stuck at ‘0’
1 FREQ1HZ 1 Hz square wave
2 FREQ32HZ 32 Hz square wave
3 FREQ64HZ 64 Hz square wave
4 FREQ512HZ 512 Hz square wave
5 ALARM_TOGGLE output toggles when alarm flag rises
6 ALARM_FLAG output is a copy of the alarm flag
7 PROG_PULSE duty cycle programmable pulse
Value Name Description
0 NO_WAVE no waveform, stuck at ‘0’
1 FREQ1HZ 1 Hz square wave
2 FREQ32HZ 32 Hz square wave
3 FREQ64HZ 64 Hz square wave
4 FREQ512HZ 512 Hz square wave
5 ALARM_TOGGLE output toggles when alarm flag rises
6 ALARM_FLAG output is a copy of the alarm flag
7 PROG_PULSE duty cycle programmable pulse
CORRECTION
3906
ppm
------------
1=