39.7.27 PWM Fault Protection Enable Register
Name: PWM_FPE
Address: 0x4002006C
Access: Read/Write
This register can only be written if bits WPSWS5 and WPHWS5 are cleared in the “PWM Write Protection Status Register” .
Only the first 8 bits (number of fault input pins) of fields FPE0, FPE1, FPE2 and FPE3 are significant.
FPEx: Fault Protection Enable for channel x
For each field bit y (fault input number):
0: Fault y is not used for the Fault Protection of channel x.
1: Fault y is used for the Fault Protection of channel x.
CAUTION: To prevent an unexpected activation of the Fault Protection, the bit y of FPEx field can be set to ‘1’ only if the corre-
sponding FPOL field has been previously configured to its final value in “PWM Fault Mode Register” .
31 30 29 28 27 26 25 24
FPE3
23 22 21 20 19 18 17 16
FPE2
15 14 13 12 11 10 9 8
FPE1
76543210
FPE0