RX_PP: Receiver Preamble Pattern detected
The following values assume that RX_MPOL field is not set:
RX_MPOL: Receiver Manchester Polarity
0: Logic zero is coded as a zero-to-one transition, Logic one is coded as a one-to-zero transition.
1: Logic zero is coded as a one-to-zero transition, Logic one is coded as a zero-to-one transition.
ONE: Must Be Set to 1
Bit 29 must always be set to 1 when programming the US_MAN register.
DRIFT: Drift Compensation
0: The USART cannot recover from an important clock drift
1: The USART can recover from clock drift. The 16X clock mode must be enabled.
Value Name Description
00 ALL_ONE The preamble is composed of ‘1’s
01 ALL_ZERO The preamble is composed of ‘0’s
10 ZERO_ONE The preamble is composed of ‘01’s
11 ONE_ZERO The preamble is composed of ‘10’s