Datasheet
460
SAM4S Series [DATASHEET]
11100F–ATARM–29-Jan-14
26.13.2 Switching from (to) Slow Clock Mode to (from) Normal Mode
When switching from slow clock mode to the normal mode, the current slow clock mode transfer is completed at high 
clock rate, with the set of slow clock mode parameters.See Figure 26-29 on page 460. The external device may not be 
fast enough to support such timings. 
Figure 26-30 illustrates the recommended procedure to properly switch from one mode to the other.
Figure 26-29. Clock Rate Transition Occurs while the SMC is Performing a Write Operation 
Figure 26-30. Recommended Procedure to Switch from Slow Clock Mode to Normal Mode or from Normal Mode to Slow Clock 
Mode 
A
[23:0]
NCS
1
MCK
NWE
1
1
NWE_CYCLE = 3
SLOW CLOCK MODE WRITE
Slow Clock Mode
internal signal from PMC
111 2
3
2
NWE_CYCLE = 7
NORMAL MODE WRITE
Slow clock mode 
transition is detected: 
Reload Configuration Wait State
This write cycle finishes with the slow clock mode set
of parameters after the clock rate transition
SLOW CLOCK MODE WRITE
A
[23:0]
NCS
1
MCK
NWE
1
1
SLOW CLOCK MODE WRITE
Slow Clock Mode
internal signal from PMC
2
3
2
NORMAL MODE WRITEIDLE STATE 
Reload Conguration
Wait State