ACEN: Analog Comparator ENable
0 (DIS) = Analog Comparator Disabled.
1 (EN) = Analog Comparator Enabled.
EDGETYP: EDGE TYPe
INV: INVert comparator output
0 (DIS) = Analog Comparator output is directly processed.
1 (EN) = Analog Comparator output is inverted prior to being processed.
SELFS: SELection of Fault Source
0 (CF) = The CF flag is used to drive the FAULT output.
1 (OUTPUT) = The output of the Analog Comparator flag is used to drive the FAULT output.
FE: Fault Enable
0 (DIS) = The FAULT output is tied to 0.
1 (EN) = The FAULT output is driven by the signal defined by SELFS.
Value Name Description
0 RISING only rising edge of comparator output
1 FALLING falling edge of comparator output
2 ANY any edge of comparator output