38.7.34 PWM Comparison x Mode Register
Name: PWM_CMPMx
Address: 0x40020138 [0], 0x40020148 [1], 0x40020158 [2], 0x40020168 [3], 0x40020178 [4], 0x40020188 [5],
0x40020198 [6], 0x400201A8 [7]
Access: Read-write
• CEN: Comparison x Enable
0 = The comparison x is disabled and can not match.
1 = The comparison x is enabled and can match.
• CTR: Comparison x Trigger
The comparison x is performed when the value of the comparison x period counter (CPRCNT) reaches the value defined by CTR.
• CPR: Comparison x Period
CPR defines the maximum value of the comparison x period counter (CPRCNT). The comparison x value is performed periodi-
cally once every CPR+1 periods of the channel 0 counter.
• CPRCNT: Comparison x Period Counter
Reports the value of the comparison x period counter.
Note: The field CPRCNT is read-only
• CUPR: Comparison x Update Period
Defines the time between each update of the comparison x mode and the comparison x value. This time is equal to CUPR+1 peri-
ods of the channel 0 counter.
• CUPRCNT: Comparison x Update Period Counter
Reports the value of the comparison x update period counter.
Note: The field CUPRCNT is read-only
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
CUPRCNT CUPR
15 14 13 12 11 10 9 8
CPRCNT CPR
76543210
CTR – – – CEN