Datasheet

906
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
38.7.25 PWM Fault Clear Register
Name: PWM_FCR
Address: 0x40020064
Access: Write-only
FCLR: Fault Clear (fault input bit varies from 0 to 5)
For each field bit y (fault input number):
0 = No effect.
1 = If bit y of FMOD field is set to 1 and if the fault input y is not at the level defined by the bit y of FPOL field, the fault y is
cleared and becomes inactive (FMOD and FPOL fields belong to “PWM Fault Mode Register” on page 904), else writing this
bit to 1 has no effect.
31 30 29 28 27 26 25 24
23 22 21 20 19 18 17 16
15 14 13 12 11 10 9 8
76543210
FCLR