Datasheet
500
42023E–SAM–07/2013
ATSAM4L8/L4/L2
20.7 Module Configuration
The specific configuration for each WDT instance is listed in the following tables.The module bus
clocks listed here are connected to the system bus clocks. Refer to Section 10. ”Power Manager
(PM)” on page 108 for details.
Table 20-2. WDT Clocks
Clock Name Description
CLK_WDT Clock for the WDT bus interface
Table 20-3. Register Reset Values
Register Reset Value
VERSION 0x00000501