Datasheet

188
42023E–SAM–07/2013
ATSAM4L8/L4/L2
12.7.13 BOD Level Register
Name: BOD18/33LEVEL
Access Type: Read/Write
Reset Value: 0x00000000
RANGE: BOD Threshold Range (available for BOD18 only)
0: The Standard Threshold Range is selected. See Section 42.9 ”Analog Characteristics” on page 1150 for actual voltage levels.
1: The Low Threshold Range is selected. See Section 42.9 ”Analog Characteristics” on page 1150 for actual voltage levels.
Note that any change to the RANGE field of the BOD18LEVEL register should be done with the BOD18 deactivated, this is to
avoid spurious resets or interrupts.
VAL: BOD Value
This field sets the triggering voltage threshold for the BOD. See Section 42.9 ”Analog Characteristics” on page 1150 for actual
voltage levels.
Note that any change to the VAL field of the BOD18/33LEVEL register should be done with the BOD deactivated, this is to avoid
spurious resets or interrupts.
31 30 29 28 27 26 25 24
RANGE------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
--------
76543210
- - VAL[5:0]