30.17.9 PMC Clock Generator PLLA Register
Name: CKGR_PLLAR
Address: 0x400E0428
Access: Read/Write
Possible limitations on PLLA input frequencies and multiplier factors should be checked before using the PMC.
Warning:
Bit 29 must always be set to 1 when programming the CKGR_PLLAR register.
This register can only be written if the WPEN bit is cleared in “PMC Write Protection Mode Register” .
DIVA: PLLA Front_End Divider
0: Divider output is stuck at 0 and PLLA is disabled.
1: Divider is bypassed (divide by 1) PLLA is enabled
2 up to 255 = clock is divided by DIVA
PLLACOUNT: PLLA Counter
Specifies the number of Slow Clock cycles before the LOCKA bit is set in PMC_SR after CKGR_PLLAR is written.
MULA: PLLA Multiplier
0: The PLLA is deactivated (PLLA also disabled if DIVA = 0).
1 up to 80 = The PLLA Clock frequency is the PLLA input frequency multiplied by MULA + 1.
ONE: Must Be Set to 1
Bit 29 must always be set to 1 when programming the CKGR_PLLAR register.
31 30 29 28 27 26 25 24
––ONE–– MULA
23 22 21 20 19 18 17 16
MULA
15 14 13 12 11 10 9 8
– – PLLACOUNT
76543210
DIVA