Datasheet

605
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
30.17.6 PMC Peripheral Clock Status Register 0
Name: PMC_PCSR0
Address: 0x400E0418
Access: Read-only
PIDx: Peripheral Clock x Status
0: The corresponding peripheral clock is disabled.
1: The corresponding peripheral clock is enabled.
Note: To get PIDx, refer to identifiers as defined in the section “Peripheral Identifiers” in the product datasheet. Other peripherals status
can be read in PMC_PCSR1 (Section 30.17.24 ”PMC Peripheral Clock Status Register 1”).
31 30 29 28 27 26 25 24
PID31 PID30 PID29 PID28 PID27 PID26 PID25 PID24
23 22 21 20 19 18 17 16
PID23 PID22 PID21 PID20 PID19 PID18 PID17 PID16
15 14 13 12 11 10 9 8
PID15 PID14 PID13 PID12 PID11 PID10 PID9 PID8
76543210
PID7–––––––