Datasheet
1411
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
46.7.10 DACC Interrupt Status Register
Name: DACC_ISR
Address: 0x400B8030
Access: Read-only
• TXRDY: Transmit Ready Interrupt Flag
0: DACC is not ready to accept new conversion requests.
1: DACC is ready to accept new conversion requests.
• EOC: End of Conversion Interrupt Flag
0: No conversion has been performed since the last DACC_ISR read.
1: At least one conversion has been performed since the last DACC_ISR read.
• ENDTX: End of DMA Interrupt Flag
0: The Transmit Counter register has not reached 0 since the last write in DACC_TCR or DACC_TNCR.
1: The Transmit Counter register has reached 0 since the last write in DACC _TCR or DACC_TNCR.
• TXBUFE: Transmit Buffer Empty
0: The Transmit Counter register has not reached 0 since the last write in DACC_TCR or DACC_TNCR.
1: The Transmit Counter register has reached 0 since the last write in DACC _TCR or DACC_TNCR.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––TXBUFEENDTXEOCTXRDY