Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
SELPLUS: Selection For Plus Comparator Input
0..7: Selects the input to apply on analog comparator SELPLUS comparison input.
ACEN: Analog Comparator Enable
0 (DIS): Analog comparator disabled.
1 (EN): Analog comparator enabled.
EDGETYP: Edge Type
INV: Invert Comparator Output
0 (DIS): Analog comparator output is directly processed.
1 (EN): Analog comparator output is inverted prior to being processed.
SELFS: Selection Of Fault Source
0 (CF): The CF flag is used to drive the FAULT output.
1 (OUTPUT): The output of the analog comparator flag is used to drive the FAULT output.
FE: Fault Enable
0 (DIS): The FAULT output is tied to 0.
1 (EN): The FAULT output is driven by the signal defined by SELFS.
Value Name Description
0 AD0 Select AD0
1 AD1 Select AD1
2 AD2 Select AD2
3 AD3 Select AD3
4 AD4 Select AD4
5 AD5 Select AD5
6 AD6 Select AD6
7 AD7 Select AD7
Value Name Description
0 RISING Only rising edge of comparator output
1 FALLING Falling edge of comparator output
2 ANY Any edge of comparator output